The diverse range of equipment and facilities produced by JUNG-ANG ENG can be engineered and
produced according to customers’ requests.
Plain Tank Lid
Plain Tank Lid
This lid is commonly used on tanks with a small diameter to block external dust and foreign substances.
Relatively light
Because it is not hermetically sealed, vacuum and pressurization are not possible.
If the tank diameter is large, the lid is hard to lift by hand.
Split Tank Lid
Round Split Tank Lid
This lid is commonly used on tanks with a large diameter to block external dust and foreign substances.
The lid is split and can be opened or fixed individually.
It can be used in combination with a motor base.
Split lid can be opened or fixed individually.
Because it is not hermetically sealed, vacuum and pressurization are not possible.
As it is not hermetically sealed, vacuum and pressurization are not possible.
Square Split Tank Lid
This lid is commonly used on tanks with a large diameter to block external dust and foreign substances. The lid is split and can be opened or fixed individually.
Split lid can be opened or fixed individually.
As it is not hermetically sealed, vacuum and pressurization are not possible.
Closed Type
Closed Type
This is the most basic structure, and is sealed by welding the top head to the shell. The structure is relatively simple, but cleaning and maintenance are inconvenient because the inside can only be accessed through the manhole.
Relatively simple structure
Hermetically sealed, so vacuum and pressurization are possible
Inconvenient cleaning and maintenance
Flange-Bolt Type
Flange-Bolt Type
With a girth flange, the lid can be separated from the shell by removing the bolts.
Vacuum and pressurization are possible
Convenient cleaning and maintenance
Hydraulic Cylinder Type
Hydraulic Cylinder Type
The lid is raised and lowered to open/close using a hydraulic cylinder.
The lid can be opened and closed conveniently with a hydraulic cylinder.